PERMITTING AND USE INFORMATION FOR JET AEROBIC SYSTEMS and JET SAND FILTERS

Technology Name To be installed in designated nitrogen sensitive area Flow design over 2000 gpd? DEP approval status DEP permit required DEP
Fee
Send application and/or permits to
JET
AEROBIC SYSTEM
YES or NO limited to 450 gpd maximum Remedial None, provided use of technology is consistent with DEP approved conditions for remedial use. If Title 5 variance req. use BRP WP 59b if needed, BRP WP 59b= $200 BRP WP 59b to DEP Regional Office
JET
SAND
FILTER
YES or NO limited to 450 gpd maximum Remedial None, provided use of technology is consistent with DEP approved conditions for remedial use. If Title 5 variance req. use BRP WP 59b if needed, BRP WP 59b= $200 BRP WP 59b to DEP Regional Office

 

Technology Name To be installed in designated nitrogen sensitive area? Is flow design over 2000 gpd? DEP approval status DEP Monitoring Requirements Nitrogen Credit in areas otherwise limited to 440 gpd/acre (systems < 2000 gpd only) Other Conditions/ Allowances for Use
JET AEROBIC
SYSTEM
YES or NO not allowed Remedial effluent quarterly for pH, BOD, TSS none must be under maintenance agreement with MA certified operator at all times. may be used in soils with perc 60-90 min/in at loading rate of 0.15 gpd/sf. 50% reduction in size of SAS or 2 ft reduction of req. groundwater separation or 2 ft reduction in req. depth of naturally occurring soil under SAS allowed.
JET
SAND
FILTER
YES or NO not allowed Remedial none none must be used as addition to an aerobic treatment plant.

must be under maintenance agreement as above.